FUEL FLEXIBLE COMBUSTION SYSTEM MODELLING WITH ZERO CARBON FUEL
This case study showcases an innovative approach to designing a fuel-flexible hydrogen combustion system…
This case study showcases an innovative approach to designing a fuel-flexible hydrogen combustion system…
This case study will describe how Flownex® was used to model a water hammer event in a pipe…
McPhy Energy Germany GmbH designs, develops, manufactures and sells technical systems and components for energy…
This case study demonstrates the capability of Flownex® to balance air distribution systems by determining the orifice sizes or damper opening…
Flownex® was used to investigate the flow distribution for a new generation John-Thomson MicroGen Boiler as steam circulation…
This case study demonstrates the capability of using Flownex® SE as a preliminary design tool for secondary flow analysis before using…
This case study demonstrates how Flownex® can be used in evaluating the effectiveness of the maintenance work conducted during…
The main challenge explored in this case study is root cause analysis of dynamically hazardous movements in the distillate lines to…
This case study demonstrates the modeling of a vapour compression refrigeration system using R22 as refrigerant. Both a steady-state…
This case study demonstrates the ability of Flownex® to be used as a tool to develop, test and implement new correlations and methods…
Faulty systems operation results in significant power generation losses. The purpose of this case study is to communicate a case where…
This case study demonstrates the use of a script and a Generic 4D chart to enable Flownex® to calculate standards-compliant wall…
This case study demonstrates the implementation of an API 560 fired heater compound component in Flownex®. It also shows how…
This case study demonstrates the use of Flownex® to model and analyse a natural gas combustion process. Several compound components…
This case study discusses the sizing of a coalescer filter and demonstrates its fouling life cycle analysis using a Flownex® model…
This case study demonstrates the implementation of a basic immersion fire-tube model in Flownex and presents natural draft and forced draft examples.
This case study investigates a pipe sizing method based on an implementation of the Generaux Equation. This method aims to…
This case study demonstrates the use of Flownex® to model simple recuperators using bare tubes in cross flow.
This case study demonstrates the implementation of two methods to account for thermal fouling factors in heat transfer piping and tubing in a…
This case study demonstrates the implementation of a compound element with external surface heat transfer to or from an external fluid…
This case study demonstrates the use of Flownex® to size properly performing pressure control valves for typical plant operation and to size and…
This case study demonstrates the use of some of Flownex’s power features – the Designer and the Sensitivity Analysis capability – during the design…
The HTGR is one of the most promising reactor concepts of the Nuclear Renaissance, offering advantages such as improved safety and…
The case study demonstrates a load following transient simulation of the Pebble Bed Micro model (PBMM). The PBMM…
This case study demonstrates the steady-state thermal fluid simulation of a shell and tube heat exchanger. The shell and tube heat exchanger…
This case study demonstrates how Flownex® and Simulink are integrated to perform different parts of a simulation. Integration of…
This case study investigates the balancing of forced flow through a perforated flow distribution manifold situated between the thermal…
This case study demonstrates the modeling of a capillary tube. Capillary tubes are used as expansion devices on some vapor-compression…
This case study demonstrates the investigation into the operating characteristics of a Reactor Cavity Cooling System (RCCS) during…
This case study demonstrates the modeling of a Combined Cycle (CC) power plant of a High Temperature Gas-Cooled Reactor (HTGR).
This case study demonstrates the steady-state simulation of a High Temperature Gas-Cooled Reactor (HTGC) nuclear power plant (NPP)…
This case study demonstrates the steady-state simulation of the fresh water (drinking water) reticulation system in a small village.
This case study demonstrates Flownex’s ability to predict the temperature rise in chilled water networks due to gravitational effects…
This case study demonstrates the capability of Flownex® to determine the orifice sizes required to ensure balanced flow in several parallel…
The objective of the simulation is to model the flow rates through the respective distribution holes of the inlet manifold. This was required…
This case study demonstrates the capability of Flownex® to simulate natural convection (buoyancy driven flow). This is done by demonstrating…
This case study demonstrates the capability of Flownex® to simulate the water hammer effect by simulating the sudden closure…
This case study demonstrates the steady-state simulation of a compressed air network used in the mining industry.
This case study demonstrates the use of Flownex® to model a natural draft exhaust stack such as those typically used in natural gas…
A blow-off test to determine compressor performance during part load conditions is required at a newly built compressor plant…
Savannah River Remediation (SRR) is a consortium of companies led by URS Corporation. It holds the Liquid Waste Operations contract at…
Eskom power utility utilized Flownex® SE simulation capabilities to mitigate system shutdowns caused by Generator Hydrogen (H2) Seal ring failures…
Application of the network approach to the modeling of three combustor types, i.e. two annular- and a reverse flow combustor, is discussed in this…
This case study reviews an AngloGold Ashanti project which facilitated a saving of 2.5 MW by using Flownex® to optimize compressor and piping…
The boiler hopper tubes at an Eskom Power Station suffer from continuous mechanical failures that lead to frequent unplanned maintenance…
As part of the repowering of a power station Steinmüller is tasked with the optimization of the boiler sub-system. This included a study to determine…
The evaporative platens gave many operational issues including header cracking causing unnecessary and costly down time due to…
Flownex® enabled M-Tech to penetrate the market by convincing clients of the economic benefit associated with the Air Cooling Units…
In this case study the endless possibilities within Flownex® are highlighted by the application of user coding and the versatility it…
This case study demonstrates the transient thermal fluid simulation of a finned tube heat exchanger. The finned tube heat exchanger model…
Re-engining of a Mirage F1 Fighter required modification of the existing aircraft refueling system. Aerosud…
A client in the petrochemical industry sought help with regards to a fired heater employed on a plant. The client wished to perform thermal…
The basic challenges faced by Midvaal Water Company were to determine the current status of the very old existing reticulation network…
Steinmüller used Flownex® to simulate a fuel oil distribution network. The Flownex® models served as a comparison study between the current…
This case study demonstrates the transient simulation of the heat transfer through a packed bed with no forced convection. This case study…
This case study demonstrates the steady-state simulation of the heat transfer through a packed pebble bed. Of particular importance…
This case study demonstrates the control of a three stage chiller plant that cools water in a primary loop, which feeds into a secondary…
Pressure regulators are to be employed at a gas-fired power station to reduce upstream gas pressures from a maximum of 15 MPa to approximately…
During the manufacturing process, tubular parts are machined and welding is performed on these parts. Before these components can be…