CS-053: RECOVERING GENERATION LOSSES DUE TO FAULTY AIR HEATER OPERATION

CS-053: RECOVERING GENERATION LOSSES DUE TO FAULTY AIR HEATER OPERATION

This case study highlights how Flownex helped detect a fault in a power plant’s Draught Group, improving generation load by 5% after correction. By comparing the Flownex model with plant measurements, abnormal readings were identified, prompting an investigation that revealed a thermocouple failure in an air heater causing a 20.1 MW loss. The early detection, combining Flownex data with plant measurements, led to a positive financial impact.

Share This:

Share This:

More Case Studies

You might also be interested in these CASE STUDIES